Electrical Safety Mats & Insulating Switchboard Matting
Protect people working on or near live equipment with insulating electrical safety mats. Our Class 0, Class 2 and Class 4 switchboard matting is tested and certified to BS EN 61111 / IEC 61111, alongside low-cost 11KV tested matting for 450 volt working, all in rolls you can cut to fit in front of switchgear, control panels and substations.
Blue Diamond Electrical Safety Matting Class 0, 2 & 4
- Insulating electrical safety matting
- Certified to BS EN 61111 / IEC 61111
- Class 0, Class 2 or Class 4
- Regulatory details printed on the back
- Fine ribbed anti-slip surface
- Natural rubber
- 100cm wide rolls or cut lengths
- Can be cut to size
- Quantity discounts available!
Blue Diamond Rubber Rib Electrical Matting 11KV (450V)
- Insulating electrical safety matting
- Tested to 11,000V, 450V working voltage
- Certified to BS 921:1976
- Fine ribbed anti-slip surface
- 6mm natural rubber
- 90, 100 or 120cm wide
- Rolls or cut lengths
- Can be cut to size
- Quantity discounts available!
Insulating Electrical Safety Mats for Switchrooms and Substations
Electrical safety mats, also called switchboard matting or insulating matting, put a non-conductive barrier between the person and the floor when working on or near live equipment. They are a simple, long-lasting control measure in front of switchgear, distribution boards, control panels, transformers, battery rooms and test benches.
Our range is made from natural rubber with a fine ribbed anti-slip surface. The Class 0, 2 and 4 mats are tested and certified to BS EN 61111 / IEC 61111 and printed on the back with their regulatory details, so the rating can be checked during inspections.
Choosing the Right Class of Electrical Safety Mat
Choose the class by the maximum working voltage of the equipment the mat will sit in front of. Always pick a class at or above your working voltage.
- Class 0 (1KV): recommended working voltage up to 1,000 volts. The usual choice for low voltage distribution boards, control panels and workshops.
- 11KV (450V): a low-cost 6mm matting tested to 11,000 volts to BS 921, with a recommended working voltage of 450 volts.
- Class 2 (17KV): recommended working voltage up to 17,000 volts, for medium voltage switchgear.
- Class 4 (36KV): recommended working voltage up to 36,000 volts, for high voltage switchrooms and substations.
Why Use Certified Switchboard Matting?
- Electrical protection: tested insulation reduces the risk of electric shock through the floor.
- Slip resistance: the fine rib surface gives good grip around equipment where trips and slips are a real hazard.
- Easy to fit: supplied in rolls that can be cut to length and size to fit the floor in front of each panel.
- Low profile: suitable for wheelchair users and light wheeled traffic.
Electrical Safety Mats FAQ
An electrical safety mat is an insulating rubber mat placed on the floor in front of live electrical equipment. It provides a non-conductive barrier that helps protect the user from electric shock through the floor. They are also known as switchboard mats, insulating mats or dielectric mats.
Choose a class at or above the maximum working voltage of the equipment. Class 0 is rated for working voltages up to 1,000 volts, Class 2 up to 17,000 volts and Class 4 up to 36,000 volts. If you are unsure, check the voltage of your switchgear or ask your electrical safety lead.
The Class 0, Class 2 and Class 4 mats are tested and certified to BS EN 61111 / IEC 61111, the international standard for electrical insulating matting. The certification details are printed on the back of the matting.
Yes. The matting is supplied in rolls and can be cut to length and size so it fits the floor area in front of each panel or piece of switchgear.
Keep the mat clean and dry, and inspect it regularly for cuts, holes, burns or contamination with oil or chemicals. Wash with cold water and avoid harsh detergents. Replace any mat that is damaged, as damage can reduce its insulating properties.